成分分析 · 材料检测 · 食品检测 · 环境检测

专业检测知识科普,帮您选对检测方案

咨询工程师

金属斜角整形外科骨折固定设备检测

发布时间:2024-06-21 作者:中析研究所 浏览:

ASTM F384-2000金属斜角整形外科骨折固定设备的标准规范和试验方法

1.1 This standard is intended to provide a comprehensive reference for angled devices used in the surgical internal fixation of the skeletal system. This standard establishes consistent methods to classify and define the geometric and performance characteristics of angled devices. This standard also presents a catalog of standard specifications that specify material and labeling and handling requirements, and standard test methods for measuring performance related mechanical characteristics determined to be important to the in vivoperformance of angled devices.1.2 It is not the intention of this standard to define levels of performance of case-specific clinical performance for angled devices, as insufficient knowledge is available to predict the consequences of their use in individual patients for specific activities of daily living. Futhermore, it is not the intention of this standard to describe or specify specific designs for angled devices used in the surgical internal fixation of the skeletal system.1.3 This standard may not be appropriate for all types of angled devices. The user is cautioned to consider the appropriateness of this standard in view of a particular angled device and its potential application.1.4 This standard includes the following test methods used in determining the following angled device mechanical performance characteristics:1.4.1 Standard test method for single cycle compression bend testing of metallic angled orthopedic fracture fixation devices (see Annex A1).1.4.2 Standard test method for determining the bending fatigue properties of metallic angled orthopedic fracture fixation devices (see Annex A2).1.5 Unless otherwise indicated, the values stated in SI units shall be regarded as the standard.Note 1--There is currently no ISO standard that is either similar to equivalent to this standard.

ASTM F384-2006金属斜角整形外科骨折固定设备的标准规范和试验方法

1.1 These specifications and test methods provide a comprehensive reference for angled devices used in the surgical internal fixation of the skeletal system. This standard establishes consistent methods to classify and define the geometric and performance characteristics of angled devices. This standard also presents a catalog of standard specifications that specify material, labeling, and handling requirements, and standard test methods for measuring performance related mechanical characteristics determined to be important to the in vivo performance of angled devices.1.2 It is not the intention of this standard to define levels of performance of case-specific clinical performance for angled devices, as insufficient knowledge is available to predict the consequences of their use in individual patients for specific activities of daily living. Futhermore, this standard does not describe or specify specific designs for angled devices used in the surgical internal fixation of the skeletal system.1.3 This standard may not be appropriate for all types of angled devices. The user is cautioned to consider the appropriateness of this standard in view of a particular angled device and its potential application.Note 1This standard is not intended to address intramedullary hip screw nails or other angled devices without a sideplate.1.4 This standard includes the following test methods used in determining the following angled device mechanical performance characteristics:1.4.1 Standard test method for single cycle compression bend testing of metallic angled orthopedic fracture fixation devices (see ).1.4.2 Standard test method for determining the bending fatigue properties of metallic angled orthopedic fracture fixation devices (see ).1.5 Unless otherwise indicated, the values stated in SI units shall be regarded as the standard.Note 2There is currently no ISO standard that is either similar to equivalent to this standard.1.6 This test method describes methods for bending fatigue testing in order to determine intrinsic structural properties of metallic angled devices. The test method may be used to determine the fatigue life at a specific or over a range of maximum bending moment levels or to estimate the fatigue strength for a specified number of fatigue cycles of an angled device.1.7 This test method is intended to provide a means to mechanically characterize different angled device designs. This test method does not define angled device performance levels since these characteristics are driven by patient-specific clinical requirements.1.8 UnitsThe values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.Note 3Currently, there is no ISO standard that is similar, or equivalent, to this test method.

ASTM F384-2006e1金属斜角整形外科骨折固定设备的标准规范和试验方法

A2.5.1 The test method establishes a uniform cantilever bending fatigue test to characterize and compare the fatigue performance of different angled device designs. This test method may be used to determine an angled device's fatigue life at either a specific or over a range of maximum bending moment conditions. Additionally, this test method may be alternatively used to estimate an angled device's fatigue strength for a specified number of fatigue cycles. A2.5.2 The test method utilizes a simplified angled device cantilever bending load model that may not be exactly representative of the in-situ loading configuration. The user should note that the test results generated by this test method can not be used to directly predict the in-vivo performance of the angled device being tested. The data generated from this test method can be used to conduct relative comparisons of different angled device designs. A2.5.3 This test method may not be appropriate for all types of implant applications. The user is cautioned to consider the appropriateness of the method in view of the devices being tested and their potential application. A2.5.4 This test method assumes that the angled device is manufactured from a material that exhibits linear-elastic material behavior; therefore, this test method is not applicable for testing angled devices made from materials that exhibit nonlinear elastic behavior. A2.5.5 This test method is restricted to the testing of angled devices within the material's linear-elastic range; therefore, this test method is not applicable for testing angled devices under conditions that would approach or exceed the bending strength of the angled device being tested.1.1 These specifications and test methods provide a comprehensive reference for angled devices used in the surgical internal fixation of the skeletal system. This standard establishes consistent methods to classify and define the geometric and performance characteristics of angled devices. This standard also presents a catalog of standard specifications that specify material, labeling, and handling requirements, and standard test methods for measuring performance related mechanical characteristics determined to be important to the in vivo performance of angled devices. 1.2 It is not the intention of this standard to define levels of performance of case-specific clinical performance for angled devices, as insufficient knowledge is available to predict the consequences of their use in individual patients for specific activities of daily living. Futhermore, this standard does not describe or specify specific designs for angled devices used in the surgical internal fixation of the skeletal system. 1.3 This standard may not be appropriate for all types of angled devices. The user is cautioned to consider the appropriateness of this standard in view of a particular angled device and its potential application. Note 18212;This standard is not intended to address intramedullary hip screw nails or other angled devices without a sideplate. 1.4 This standard includes the following test methods used in determining the following angled device mechanical performance characteristics: 1.4.1 Standard test method for single cycle compression bend testing of metallic angled orthopedic fracture fixation devices (see Annex A1). 1.4.2 Standard test method for determining the bending fatigue properties of metallic angled orthopedic fracture fixation devices (see Annex A2). 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

ASTM F384-2012金属斜角整形外科骨折固定设备的标准规范和试验方法

A2.5.1 The test method establishes a uniform cantilever bending fatigue test to characterize and compare the fatigue performance of different angled device designs. This test method may be used to determine the fatigue life of an angled device at either a specific or over a range of maximum bending moment conditions. Additionally, this test method may be alternatively used to estimate the fatigue strength of an angled device for a specified number of fatigue cycles. A2.5.2 The test method utilizes a simplified angled device cantilever bending load model that may not be exactly representative of the in-situ loading configuration. The user should note that the test results generated by this test method can not be used to directly predict the in-vivo performance of the angled device being tested. The data generated from this test method can be used to conduct relative comparisons of different angled device designs. A2.5.3 This test method may not be appropriate for all types of implant applications. The user is cautioned to consider the appropriateness of the method in view of the devices being tested and their potential application. A2.5.4 This test method assumes that the angled device is manufactured from a material that exhibits linear-elastic material behavior; therefore, this test method is not applicable for testing angled devices made from materials that exhibit nonlinear elastic behavior. A2.5.5 This test method is restricted to the testing of angled devices within the linear-elastic range of the material; therefore, this test method is not applicable for testing angled devices under conditions that would approach or exceed the bending strength of the angled device being tested. 1.1 These specifications and test methods provide a comprehensive reference for angled devices used in the surgical internal fixation of the skeletal system. This standard establishes consistent methods to classify and define the geometric and performance characteristics of angled devices. This standard also presents a catalog of standard specifications that specify material, labeling, and handling requirements, and standard test methods for measuring performance related mechanical characteristics determined to be important to the in vivo performance of angled devices. 1.2 It is not the intention of this standard to define levels of performance or case-specific clinical performance for angled devices, as insufficient knowledge is available to predict the consequences of their use in individual patients for specific activities of daily living. Futhermore, this standard does not describe or specify specific designs for angled devices used in the surgical internal fixation of the skeletal system. 1.3 This standard may not be appropriate for all types of angled devices. The user is cautioned to consider the appropriateness of this standard in view of a particular angled device and its potential application. Note 18212;This standard is not intended to address intramedullary hip screw nails or other angled devices without a sideplate. 1.4 This standard includes the following test methods used in determining the following angled device mechanical performance characteristics: 1.4.1 Standard test method for single cycle compression bend testing of metallic angled orthopedic fracture fixation devices (see Annex A1). 1.4.2 Standard test method for determining the bending fatigue properties of metallic angled orthopedic fracture fixation devices (see Annex A2). 1.5 The values stated in SI units are to be regarded as standard. No other units of me......

ASTM F384-2017金属斜角整形外科骨折固定设备的标准规范和试验方法

A2.5x00a0;Significance and Use A2.5.1x00a0;The test method establishes a uniform cantilever bending fatigue test to characterize and compare the fatigue performance of different angled device designs. This test method may be used to determine the fatigue life of an angled device at either a specific or over a range of maximum bending moment conditions. Additionally, this test method may be alternatively used to estimate the fatigue strength of an angled device for a specified number of fatigue cycles. A2.5.2x00a0;The test method utilizes a simplified angled device cantilever bending load model that may not be exactly representative of the in-situ loading configuration. The user should note that the test results generated by this test method can not be used to directly predict the in-vivo performance of the angled device being tested. The data generated from this test method can be used to conduct relative comparisons of different angled device designs. A2.5.3x00a0;This test method may not be appropriate for all types of implant applications. The user is cautioned to consider the appropriateness of the method in view of the devices being tested and their potential application. A2.5.4x00a0;This test method assumes that the angled device is manufactured from a material that exhibits linear-elastic material behavior; therefore, this test method is not applicable for testing angled devices made from materials that exhibit nonlinear elastic behavior. A2.5.5x00a0;This test method is restricted to the testing of angled devices within the linear-elastic range of the material; therefore, this test method is not applicable for testing angled devices under conditions that would approach or exceed the bending strength of the angled device being tested. 1.1x00a0;These specifications and test methods provide a comprehensive reference for angled devices used in the surgical internal fixation of the skeletal system. This standard establishes consistent methods to classify and define the geometric and performance characteristics of angled devices. This standard also presents a catalog of standard specifications that specify material, labeling, and handling requirements, and standard test methods for measuring performance related mechanical characteristics determined to be important to the in vivo performance of angled devices. 1.2x00a0;It is not the intention of this standard to define levels of performance or case-specific clinical performance for angled devices, as insufficient knowledge is available to predict the consequences of their use in individual patients for specific activities of daily living. Futhermore, this standard does not describe or specify specific designs for angled devices used in the surgical internal fixation of the skeletal system. 1.3x00a0;This standard may not be appropriate for all types of angled devices. The user is cautioned to consider the appropriateness of this standard in view of a particular angled device......

上一篇外科植入物 医用金属接骨螺钉检测 下一篇钨、钼矿石检测

相关阅读

了解更多检测知识

道桥材料检测

道桥材料检测覆盖水泥、沥青、集料、钢筋及结构混凝土等对象,通过取样规范、力学试验、化学分析与无损检测等手段,测定强度、变形、耐久等关键指标。本文按样品制备、检测方法、指标测定到判定标准的步骤展开,说明各环节操作要点,并给出第三方检测机构的选择要素,可用于工程质量控制与验收参考。

2026-11-13 | [其他]

洗衣凝珠检测

洗衣凝珠检测围绕成分、性能与安全三大维度展开,涵盖取样规范、HPLC法测定活性物含量、表面活性剂鉴定与酶活分光光度法测定、去污力与溶解性能试验、微生物限量与重金属指标判定。本文按流程分述各检测方法与操作要点,供质量控制与委托检测参考。

2026-11-09 | [其他]

绿色食品检测

绿色食品检测覆盖农药残留、重金属、微生物限量及理化品质等维度。本文按样品制备、GC-MS农残测定、ICP-MS重金属测定、平板计数法微生物检验的顺序说明操作要点,并阐述灵敏度、回收率等方法验证指标与判定标准,适合标志申报与质量控制场景参考。

2026-11-07 | [其他]

吐鲁番葡萄检测

吐鲁番葡萄检测围绕样品采集制备、农药残留GC-MS与HPLC分析、糖度及营养成分分光光度测定、重金属与微生物联检等环节展开。检测依据食品安全国家标准中的限量要求判定,报告可用于收购分级、市场准入及地理标志产品核查,检测流程规范、结果可追溯。

2026-10-31 | [其他]

食品过敏原检测

食品过敏原检测覆盖样本制备、ELISA蛋白筛查、PCR基因成分鉴定及LC-MS/MS质谱确证等环节。检测针对乳、蛋、花生、坚果、麸质等常见致敏成分,以检出限、特异性、回收率等指标评价方法性能,判定结果用于交叉污染控制、标签标示与进出口合规管理。

2026-10-29 | [其他]

二硫化钼检测

二硫化钼检测围绕物相结构、微观形貌、粒度分布与化学纯度展开,常用X射线衍射鉴别2H与1T晶型及杂相,拉曼光谱判断层数与缺陷状态,扫描电镜观察颗粒形貌,激光粒度法测定粒径分布,ICP光谱定量杂质元素。本文按制样、表征、指标判定的流程介绍各方法操作要点与适用场景。

2026-10-29 | [其他]

我们的优势

选择中析研究所的八大理由

资质齐全

旗下实验室依法依规开展检测,报告科学公正,获监管与客户广泛认可。

设备先进

上千台精密仪器定期检定校准,量值溯源体系完善。

专家团队

多领域技术专家,十年以上经验,破解各类疑难检测。

标准覆盖广

覆盖GB、行标及ISO、ASTM等国际标准,可定制方案。

周期短

常规项目7-10个工作日出报告,流程标准高效。

加急服务

支持加急检测通道,助力客户快速完成质量把关。

一对一服务

工程师全程对接,需求沟通到报告解读全流程陪伴。

数据保密

严格保密制度,客户样品与检测数据安全无忧。

旗下实验室资质

我司旗下实验室具备CMA资质认定及CNAS认可,具体项目是否在资质认定/实验室认可范围内请与工程师确认。

CMA检验检测机构资质认定证书

CMA检验检测机构资质认定证书

CNAS实验室认可证书

CNAS实验室认可证书

ISO管理体系认证证书

ISO管理体系认证证书

高新技术企业证书

高新技术企业证书

中国分析测试协会会员单位

中国分析测试协会会员单位

中国质量协会会员证书

中国质量协会会员证书

AAA级信用企业证书

AAA级信用企业

绿色低碳诚信示范创建企业证书

绿色低碳诚信示范创建企业

仪器设备

1000余台精密设备 · 点击查看原图

气相色谱-质谱联用仪

气相色谱-质谱联用仪 GC-MS

复杂有机组分的定性鉴定与未知物剖析利器。

高效液相色谱仪

高效液相色谱仪 HPLC

食品添加剂、药品成分等热敏物质的精准检测。

电感耦合等离子体发射光谱仪

电感耦合等离子体发射光谱仪 ICP-OES

一次进样同时读出数十种金属元素含量。

傅里叶变换红外光谱仪

傅里叶变换红外光谱仪 FTIR

通过特征吸收峰快速判断材料种类与分子结构。

X射线荧光光谱仪

X射线荧光光谱仪 XRF

几分钟完成元素快检,且不损伤样品。

扫描电子显微镜

扫描电子显微镜 SEM

放大数十万倍观察表面微观结构,锁定失效根源。

液相色谱-质谱联用仪

液相色谱-质谱联用仪 LC-MS

农兽药残留等痕量物质的高灵敏确证检测。

气相色谱仪

气相色谱仪 GC

溶剂残留、香气成分等挥发性物质的专业检测。

在线工程师 一对一服务

检测需求不知从何入手?立即联系在线工程师,一对一解答检测疑问,免费获取检测方案与报价。

VR实验室720°全景 NEW · 全新上线 VR实验室上线啦! 720°全景实景观览 · 足不出户走进实验室 立即体验 检测咨询 · 立即在线沟通