欢迎访问中科光析科学技术研究所官网!
免费咨询热线
400-635-0567
舒适风扇和调速器检测项目报价? 解决方案? 检测周期? 样品要求? |
点 击 解 答 ![]() |
本部分规定了家用和类似用途电器的基本术语。本部分适用于家用和类似用途电器相关标准的制修订以及其他相关技术文件的编制和技术交流活动。
本标准规定了农林拖拉机和机械操作者位置处噪声的测量方法。本标准适用于操作者乘座操纵或步行操纵的拖拉机和机械,测量的噪声只与机械本身有关。 本标准规定的测试程序与GB/T14259中简易法的测试程序相同。 本标准还规定了农林拖拉机和机械操作者位置处噪声测量和记录的基本要求。在下列附录中规定了各种类型机械噪声测量的附加条件: 附录A(标准的附录)农林拖拉机 附录B(标准的附录)自走式农业机械 附录C(标准的附录)步行操纵式农业机械 附录D(标准的附录)林业集运机和集材拖拉机 测量期间,规定的机械运行状态,应使测量的噪声为真正的和可重复测定的,并且是操作者在操纵机械时能够遭受到的大噪声。
本规范适用于电压等级为35kV及以下建筑电气安装工程的施工质量验收。
本规范适用于工业与民用建筑物、构筑物中电气照明装置安装工程的施工与工程交接验收。
本规范适用于蒸汽初参数为超高压及以上、单台机组容量在125MW及以上,采用直接燃烧方式、主要燃用固体化石燃料的火力发电厂工程的设计。
本规范适用于新建、改建、扩建的水电工程的劳动安全与工业卫生设计。
This part of BS 5655 gives recommendations for the modernization, or modification, and improvement ofelectric passenger and goods passenger lifts, with traction drive or positive drive, serving defined landinglevels, having a car designed for the transportation of persons or persons and goods, suspended by ropes orchains and moving between guide rails inclined not more than 15° to the vertical.This part of BS 5655 does not cover any of the following types of lift:a) new lifts;b) lifting appliances, such as paternosters, mine lifts, theatrical lifts, appliances with automatic caging,skips, lifts and hoists for building and public works sites, ship’s hoists, platforms for exploration ordrilling at sea, construction and maintenance appliances;c) installations where the inclination of the guide rails to the vertical exceeds 15°;d) lifts with drives other than traction drives or positive drives;e) like-for-like replacement of lift components;f) goods only lifts.NOTE 1 The recommendations in this part of BS 5655 may, however, be used as a basis for modernization or modification of such lifts.NOTE 2 Where a lift falls into one of the following categories, it is deemed to be a new lift as defined in the LiftsRegulations 1997 [1] and this part of BS 5655 is not applicable:— dismantled from an existing site and installed at a new site;— installed where no lift previously existed;— completely replaced;— only retains the guide rails.NOTE 3 In some situations (e.g. potentially explosive atmosphere, extreme climate conditions, vandalism, transporting dangerousgoods, etc.), additional measures might need to be taken to those recommended in this part of BS 5655.
This part of BS 5655 gives recommendations for the modernization, or modification, and improvement of hydraulic passenger and goods passenger lifts, serving defined landing levels, having a car designed for the transportation of persons or persons and goods, suspended by jacks, ropes or chains and moving between guide rails inclined not more than 15° to the vertical.This part of BS 5655 does not cover any of the following types of lift:a) new lifts (see Note 2);b) lifting appliances, such as paternosters, mine lifts, theatrical lifts, appliances with automatic caging,skips, lifts and hoists for building and public works sites, ship’s hoists, platforms for exploration ordrilling at sea, construction and maintenance appliances;c) installations where the inclination of the guide rails to the vertical exceeds 15°;d) lifts with drives other than hydraulic lifts suspended by jacks, ropes or chains;e) like-for-like replacement of lift components (see 3.2);f) goods only lifts;g) lifts with rated speeds, upwards or downwards, greater than 1.0 m/s.NOTE 1 The recommendations in this part of BS 5655 may, however, be used as a basis for modernization or modification of such lifts.NOTE 2 Where a lift falls into one of the following categories, it is deemed to be a new lift as defined in the LiftsRegulations 1997 [1] and this part of BS 5655 is not applicable:— dismantled from an existing site and installed at a new site;— installed where no lift previously existed;— completely replaced;— only retains the guide rails.NOTE 3 In some situations (e.g. potentially explosive atmosphere, extreme climate conditions, vandalism, transporting dangerousgoods, etc.), additional measures might need to be taken to those recommended in this part of BS 5655.