欢迎访问中科光析科学技术研究所官网!

免费咨询热线
|
疾病控制样品检测项目报价? 解决方案? 检测周期? 样品要求? |
点 击 解 答 ![]() |
GB 21551的本部分规定了家用和类似用途电器(以下简称“家用电器”)中使用的抗菌材料、零部件的抗菌及抗霉菌(以下简称“抗菌”)性能试验方法和效果评价等。本部分适用于家用电器中使用的抗菌材料及相关抗菌零部件进行抗菌性能试验的方法和效果评价。
本标准规定了食品毒理学检测实验室质量控制的管理要求、技术要求、过程控制要求和结果质量控制要求。本标准包括食品毒理学检测实验室从受理申请、样品采集、样品处理及样品检验到出具检验报告、解释结果及提出建议全过程的质量控制要求。本标准适用于食品毒理学检测实验室,亦可供其他毒理学检测实验室参考使用。
本标准规定了测量结果不确定度的四种评定方法。本标准适用于检测实验室的测量不确定度评定。
本标准规定了核电厂职业照射监测的一般要求、不同类别监测的技术要求及其监测结果评价和质量保证。本标准适用于为控制核电厂职业照射而进行的辐射监测。核电厂以外的其他核反应堆运行单位可参照使用。
本标准规定了卫生检测与评价实验室名词术语的分类和定义(或含义)。本标准适用于卫生检测与评价工作,特别是卫生检测技术标准(规范)的编写和实施。
本标准规定了用于检测牡蛎闭合孢子虫病的临床诊断方法、组织印迹法、组织切片法、透射电镜法、PCR方法和核酸原位杂交等方法。本标准适用于闭合孢子虫病的流行病学调查、监测、诊断和出入境检验检疫。
本标准规定了系统受控下基于质量控制和确认数据的测量不确定度评定。本标准适用于化学领域检测实验室的测量不确定度评定。
The present Part of the Standard specifies the identification and quantificationprocedures of the sampled PCDDs/PCDFs. It is an integral part of the complete measurement procedure. The use of the other two parts of this Standard, EN 1948-1:2003 and EN 1948-2:2003, describing sampling and extraction and clean-up, respectively, is necessary for the determination of the PCDDs/PCDFs. This Standard has been designed to measure PCDD/PCDF concentrations at about 0,1 ng I-TEQ/m cube in stationary source emissions.
This International Standard specifies a method that is applicable for the detection and enumeration of Cryptosporidium oocysts and Giardia cysts on or in food products that are described herein as fresh leafy green vegetables and berry fruits. With suitable controls, it may also be applicable for the examination of other fresh produce.
This document defines general terms which are help-ful for the communication within the aluminium indus-try and its customers relating to the chemical analysis.\nA glossary (Annex A) comprises all terms in alpha-betical order which are defined in this document.\nNOTE Most of the definitions are taken from or closely adapted to ISO standards and/or VIM.
IEC 62321, which is an International Standard, specifies the determination of the levels oflead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (Cr(VI)) contained in inorganicand organic compounds, and two types of brominated flame retardants, polybrominatedbiphenyls (PBB) and polybrominated diphenyl ethers (PBDE) contained in electrotechnicalproducts.This standard refers to the sample as the object to be processed and measured. The natureof the sample and the manner in which it is acquired is defined by the entity carrying out thetests and not by this standard.NOTE 1 Further guidance on obtaining representative samples from finished electronic products to be tested forlevels of regulated substances may be found in the future IEC Publicly Available Specification (PAS) for samplingdisjointment1.It is noted that the selection of the sample may affect the interpretation of the test results.This standard does not determine:• the definition of a “unit” or “homogenous material” as the sample;• the disassembly procedure employed for obtaining a sample;• assessment procedures.NOTE 2 Further guidance on assessment procedures may be found in the future IEC Technical SpecificationIEC/TS 62476
前沿科学
微信公众号
中析研究所
抖音
中析研究所
微信公众号
中析研究所
快手
中析研究所
微视频
中析研究所
小红书