欢迎访问中科光析科学技术研究所官网!

免费咨询热线
400-640-9567|
聚氯乙烯地下排水和污水管材和管件检测项目报价? 解决方案? 检测周期? 样品要求? |
点 击 解 答 ![]() |
The document specifies general requirements and tests for pipes of unplasticized polyvinylchloride (PVC-U) with dimensions according to DIN 8062.
This part of the standard contains general requirements and performance criteria for large-diameter pipes and fittings made of thermoplastic materials with profiled wall and smooth pipe inner surface for buried applications.
This Part fo EN 12666 specifies the requirements for pipws, fittings and the system of polyethylene(PE) piping systems intended to be used for --non-pressure underground drainage and sewerage outside the building structure
This standard defines a method of specifying delivery conditions for poly(vinyl chloride) (PVC) recyclates.L It gives the most important characteristics and associated test methods for assessing of PVC recyclates intended for use in the production of semi-finished/finished products.
This European Standard specifies the requirements for pipes, fittings and the system of styrene copolymer blends (SAN+PVC) solid-wall piping systems in the field of soil and waste discharge (low and high temperature) inside buildings (marked with "B") and for soil and waste discharge systems for both inside buildings and buried in ground within the building structure (marked with "BD").nNOTE 1: The application area "inside buildings" according to this standard, applies to the interior area of the building only. The application area "within the building structure" conforms to the requirements for "inside buildings" according to prEN 12056-1.nIt also specifies the test parameters for the test methods referred to in this standard.nThis standard is applicable to (SAN+PVC) pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for the following purposes:na) soil and waste discharge pipework for the conveyance of domestic waste waters (low and high temperature);nb) ventilation pipework associated with a);nc) rainwater pipework within the building structure.nIt applies to pipes and fittings, marked with "B", which are intended to be used inside buildings and outside buildings fixed onto the wall.nIt applies to pipes and fittings, marked with "BD", which are intended to be used for both inside buildings and buried in ground within the building structure.nNOTE 2: Only components marked with "BD" are generally to be used buried in ground within the building structure; these are required to have a nominal ring stiffness of at least SN 4 and a nominal outside diameter equal or greater than 75 mm.nNOTE 3: Pipes and fittings of the pipe series S 25 are intended to be used for application area "B" only. nThis standard is applicable to (SAN+PVC) pipes and fittings of the following types:n- plain-ended;n- with integral elastomeric ring seal socket;n- with integral solvent cement socket;n- with integral dual purpose socket for elastomeric ring seal joints and/or solvent cement joints,nwhereby the fittings can be manufactured by injection-moulding or be fabricated from pipes and/or mouldings.nNOTE 4: Components conforming to any of the Product Standards listed in the bibliography can be used with pipes and fittings conforming to this standard, provided they conform to the requirements for joint dimensions and to the functional requirements given in this standard.nThis standard covers a range of nominal sizes, a range of pipe series and gives recommendations concerning colours.nNOTE 5: It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices codes.
This European Standard specifies the requirements for pipes, fittings and the piping system of chlorinated poly(vinyl chloride) (PVC-C) solid-wall piping systems in the field of soil and waste discharge (low and high temperature) inside buildings (marked with "B") and for soil and waste discharge systems for both inside buildings and buried in ground within the building structure (marked with "BD").nNOTE 1: The application area "inside buildings", according to this standard, applies to the interior area of the building only. The application area "within the building structure" conforms to the requirements for "inside buildings" according to prEN 12056-1.nIt also specifies the test parameters for the test methods referred to in this standard.nThis standard is applicable to PVC-C pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for the following purposes:na) soil and waste discharge pipework for the conveyance of domestic waste waters (low and high temperature);nb) ventilation pipework associated with a);nc) rainwater pipework within the building structure.nIt applies to pipes and fittings marked with "B", which are intended to be used inside buildings and outside buildings fixed onto the wall.nIt applies to pipes and fittings, marked with "BD", which are intended to be used for both inside buildings and buried in ground within the building structure.nNOTE 2: Only components marked with "BD" are generally to be used buried in ground within the building structure; these are required to have a nominal ring stiffness of at least SN 4 and a nominal outside diameter equal to or greater than 75 mm.nNOTE 3: Pipes and fittings of the pipe series S 25 are intended to be used for application area "B" only. nThis standard is applicable to PVC-C pipes and fittings of the following types:n- plain-ended;n- with integral elastomeric ring seal socket;n- with integral solvent cement socket;n- with integral dual purpose socket for elastomeric ring seal joints and/or solvent cement joints;nwhereby the fittings can be manufactured by injection-moulding or be fabricated from pipes and/or mouldings.nNOTE 4: Components conforming to any of the Product Standards listed in the bibliography can be used with pipes and fittings conforming to this standard, provided they conform to the requirements for joint dimensions and to the functional requirements given in this standard.nThis standard covers a range of nominal sizes, a range of pipe series and gives recommendations concerning colours.nNOTE 5: It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices codes.
This part of ISO 1452 specifies the general aspects of unplasticized poly(vinyl chloride) (PVC-U) solid-wall piping systems intended for water supply and for buried and above-ground drainage and sewerage under pressure.In conjunction with ISO 1452-2, ISO 1452-3, ISO 1452-4 and ISO 1452-5, it is applicable to PVC-U pipes, fittings, valves and ancillary equipment, their joints and to joints with components of other plastics and nonplastics materials intended to be used for the following:a) water mains and services buried in the ground;b) conveyance of water above ground for both outside and inside buildings;c) buried and above-ground drainage and sewerage under pressure.It is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C(cold water), intended for human consumption and for general purposes as well as for waste water underpressure.This part of ISO 1452 is also applicable to components for the conveyance of water and waste water up to and including 45 °C. For temperatures between 25 °C and 45 °C, Figure A.1 of ISO 1452-2:2009 applies.NOTE The producer and the end-user can come to agreement on the possibilities of use for temperatures above 45 °C on a case-by-case basis.
This part of ISO 1452 specifies the characteristics of solid-wall pipes made from unplasticized poly(vinyl chloride) (PVC-U) for piping systems intended for water supply and for buried and above-ground drainage and sewerage under pressure.It also specifies the test parameters for the test methods referred to in this part of ISO 1452.In conjunction with ISO 1452-1 and ISO 1452-5, it is applicable to extruded PVC-U pipes without a socket and pipes with a socket (integral or not), intended to be used for the following:a) water mains and services buried in the ground;b) conveyance of water above ground for both outside and inside buildings;c) buried and above-ground drainage and sewerage under pressure.It is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C(cold water) intended for human consumption and for general purposes as well as for waste water underpressure.This part of ISO 1452 specifies pipes for the conveyance of water and waste water up to and including 45 °C.For temperatures between 25 °C and 45 °C, Figure A.1 applies.NOTE 1 The producer and the end-user can come to agreement on the possibilities of use for temperatures above 45 °C on a case-by-case basis.This part of ISO 1452 specifies a range of pipe sizes and pressure classes, and gives requirementsconcerning colours.NOTE 2 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
This International Standard specifies a method for testing the ring flexibility of a thermoplastics pipe having acircular cross-section.The method enables determination of the deflection, and necessary force, at which physical damage, if any,occurs within the specified diametric deflection.
前沿科学
微信公众号
中析研究所
抖音
中析研究所
微信公众号
中析研究所
快手
中析研究所
微视频
中析研究所
小红书