为提高我国坡屋面工程技术水平,确保工程质量,制定本规范。本规范适用于新建、扩建和改建的工业建筑、民用建筑坡屋面工程的设计、施工和质量验收。坡屋面工程的设计和施工应遵守有关环境保护、建筑节能和安全的规定,并应采取相应措施。 坡屋面工程应积极采用成熟的新材料、新技术、新工艺。坡屋面工程的设计、施工和质量验收除应符合本规范外,尚应符合现行有关标准的规定。
本规程适用于工业与民用建筑屋面板(非上人屋面)、墙面板、天花板、内隔墙、声屏障等的设计及安装。
本规程适用于工业与民用建筑采用的围护结构、轻型屋面、吊顶板等用的非金属面结构保温夹芯板的设计。
本标准规定了金属面硬质酚醛泡沫复合板产品的术语和定义、分类和标记、金属面层材料、技术要求、试验方法、检验规则以及标志、包装、运输和贮存。本标准适用于工业与民用建筑通风、空调系统风管用金属面硬质酚醛泡沫复合板。
本标准规定了建筑用金属面酚醛泡沫夹芯板产品的术语和定义、分类和标记、原材料、要求、试验方法、检验规则以及包装、运输和贮存等。本标准适用于以彩色涂层钢板为面层工厂化生产的工业与民用建筑外墙、隔墙、屋面、天花板的酚醛泡沫夹芯板。其他用途时可参照本标准执行。
本标准规定了建筑结构保温复合板的术语和定义、分类和标记、材料、要求、试验方法、检验规则、标志及包装、运输与贮运等。本标准适用于建筑非承重围护结构用保温复合墙板。
本规程适用于新建、扩建和改建的民用建筑中采用保温防火复合板的外墙外保温工程的设计、施工及质量验收。
This European Standard specifies the requirements for factory made mineral wool products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the mat blankets, boards or slabs.Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.Products with a declared thermal resistance lower than 0,25 m2 K/W or a declared thermal conductivity greater than 0,060 W/(m·K) at 10 °C are not covered by this standard. This standard does not cover in situ insulation products (covered by EN 14064 parts 1 and 2) and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14303).
This European Standard specifies the requirements for factory made products of extruded polystyrene foam, with or without facings or coatings, which are used for thermal insulation of buildings. The products are manufactured in the form of boards, which are also available with special edge and surface treatment (tongue & grooves, shiplap etc.). This standard includes XPS multi-layered insulation boards with layers perpendicular to the edges of the board, i.e. layers parallel to the surface of the final board.Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered.This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.The standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.Products with a declared thermal resistance lower than 0,25 m2 K/W or a declared thermal conductivity greater than 0,060 W/(m·K) at 10 °C are not covered by this standard.This standard does not cover in situ insulation products, nor products intended to be used for the insulation of building equipment and industrial installations, or civil engineering applications or acoustic insulation.
This European Standard specifies the requirements for factory made phenolic foam products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards and laminates. Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. Products with a declared thermal resistance lower than 0,40 m2K/W or a declared thermal conductivity greater than 0,050 W/(mK) at 10 °C are not covered by this standard. This standard does not cover in-situ thermal insulation products, products intended to be used for the thermal insulation of building equipment and industrial installations (covered by EN 14314 (3)).
This European Standard specifies the requirements for factory made cellular glass (CG) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or slabs.This standard includes CG multi-layered insulation products. Instructions of Annex C shall be followed.Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.Products with a declared thermal resistance lower than 0,50 m2 K/W or a declared thermal conductivity greater than 0,065 W/(m·K) at 10 °C are not covered by this standard.This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.
This European Standard specifies the requirements for factory made wood wool (WW) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or slabs.This European Standard also specifies the requirements for the factory made composite products, made from wood wool in combination with other insulation materials. This standard includes WW multilayered insulation products. Instructions of annex C shall be followed. This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.Products covered by this European Standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels and classes required for a given application are to be found in regulations or non conflicting standards.Products with a declared thermal resistance lower than 0,15 m2 K/W or a declared thermal conductivity greater than 0,100 W/(m·K) at 10 °C are not covered by this standard.This European Standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.
This European standard specifies the requirements for factory made expanded perlite board (EPB) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards, multi layered insulation or composite insulation products.This standard includes EPB multi-layered insulation products. Instructions of Annex D shall be followed.This standard also covers composite insulation products (see Annex E).Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered.This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non conflicting standards.Products with a declared thermal resistance lower than 0,15 m2 K/W or a declared thermal conductivity greater than 0,070 W/(m·K) at 10 °C are not covered by this standard.This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations. This standard does not cover the following acoustical aspects: acoustic absorption index and direct airborne sound insulation.
This European Standard specifies the requirements for factory made wood fibre (WF) products, with or without facings or coatings, which are used for the thermal insulation of buildings ). The products are manufactured in the form of rolls, batts, felts, boards or slabs.This standard includes WF multi-layered insulation products. Instructions of Annex C shall be followed.Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The classes and levels required for a given application are to be found in regulations or non-conflicting standards.Products with a declared thermal resistance lower than 0,20 m2 K/W or a declared thermal conductivity greater than 0,070 W/(m·K) at 10 °C are not covered by this standard.This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.
This European Standard specifies the characteristics and performance of thermal/acoustic insulation composite panels made of an insulating material laminated to gypsum boards for which the main intended use is the internal insulation (thermal and/or acoustic) of walls. They are attached with adhesives or by mechanical fixings to vertical solid backgrounds and by mechanical fixings to wood or metal framing with the gypsum board face exposed. The method of fixing and jointing should ensure that the insulating material is not exposed in its normal application. This European Standard covers the following performance characteristics: reaction to fire, fire resistance, water vapour permeability, flexural strength, impact resistance, direct airborne sound insulation and thermal resistance to be measured according to the corresponding European test methods. It provides for the assessment and verification of constancy of performance of the products to this European Standard. This European Standard covers also additional technical characteristics that are of importance for the use and acceptance of the product by the construction industry.
for the thermal insulation of building equipment and industrial installations with an operating temperature range of approximately 0 °C to + 800 °C. Below an operating temperature of ambient, special means against water vapour diffusion and water accumulation by air flow might be required. Below an operating temperature of - 50 °C, special tests regarding the suitability of the products in the intended application are advised (e. g. liquefaction of oxygen). Manufacturer's advice should be heeded in all cases. The products are manufactured with or without facings or coatings, in the form of rolls, boards, slabs, mats, felts, quilts, wired mats, lamella mats, bevelled lags and pipe sections. This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required level of a given property that should be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application can be found in regulations and invitations to tender. Products with a declared thermal conductivity greater than 0,065 W/(m·K) at 10 °C are not covered by this standard. This European Standard does not cover products for in situ insulation (blowing or pouring) or products for the insulation of the building structure. This European Standard does not cover the following acoustical aspects: direct airborne sound insulation and impact noise transmission index.
This European Standard specifies the requirements for factory made cellular glass products which are used for the thermal insulation of building equipment and industrial installations with an operating temperature range of approximately - 265 °C to + 430 °C. Below an operating temperature of - 50 °C, special tests regarding the suitability of the product in the intended application are advised (e. g. liquefaction of oxygen). Manufacturer's advice should be heeded in all cases. The products are manufactured in the form of faced or unfaced boards, pipe sections, segments and prefabricated ware. This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required level of a given property that should be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application can be found in regulations and invitations to tender. Products with a declared thermal conductivity greater than 0,065 W/(m·K) at 10 °C are not covered by this standard. This European Standard does not cover products for the insulation of the building structure.
This European Standard specifies the requirements for factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products, with a closed cell content not less than 90 %, with or without facings, which are used for the thermal insulation of building equipment and industrial installations, with an operating temperature range of approximately, - 200 °C to + 200 °C. Below an operating temperature of - 50 °C, special tests regarding the suitability of the products in the intended application are advised (e. g. liquefaction of oxygen). Manufacturer's advice should be heeded in all cases. The products are manufactured in the form of blocks, faced or unfaced boards, pipe sections, segments and prefabricated ware. This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required level of a given property that should be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations and invitations to tender. Products with a declared thermal conductivity greater than 0,100 W/(m·K) at 10 °C are not covered by this European Standard. This European Standard does not cover products for in situ-insulation (spraying or dispensing) or products for the insulation of the building structure. This European Standard does not cover the following acoustical aspects: direct airborne sound insulation and impact noise transmission index.
This European Standard specifies the requirements for factory made phenolic foam products which are used for the thermal insulation of building equipment and industrial installations with an operating temperature in the range of approximately - 200 °C to + 120 °C. Below an operating temperature of - 50 °C, special tests regarding the suitability of the products in the intended application are advised (e. g. liquefaction of oxygen). Manufacturer's advice should be heeded in all cases. The products are manufactured in the form of blocks, faced or unfaced, boards, pipe sections, segments and prefabricated ware. This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required level of a given property that should be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application can be found in regulations and invitations to tender. Products with a declared thermal conductivity greater than 0,050 W/(m·K) at 10 °C are not covered by this standard. This European Standard does not cover products for in situ-insulation (blowing or pouring) or products for the insulation of the building structure. This European Standard does not cover the following acoustical aspects: direct airborne sound insulation and impact noise transmission index.